- 93 -
11-2 Check B
B1. LED blinks once, then repeats (FCT0 Fault: A-Inverter)
- Purpose: Detecting motor current and voltage error
- Check voltage at
point A
(Motor Voltage),
point B
(Motor Current) and
Point C
(Capacitor
Voltage) when
compressor is off
.
- Spec:
Points A, B,
&
C 2.5V
±
0.3V
Protection Logic
Blink
OFF Blink OFF
Y
N
Protection
logic
Check B
Blink 1 time
(FCT 0) Check B1
Out of spec?
(2.2 - 2.8V)
Reset Power
Replace Driver PCB
B2. LED blinks two times, then repeats (Stroke Trip: A & E Inverters)
Protection Logic
Blink
Blink OFF Blink Blink OFF
Y
Y
Y
Y
Protection
logic
Check B
Blink 2 times
(Stroke Trip) Check B2
Compressor
Doesn't work
Y
N
Compressor
Works Intermittently
Capacitor
Spec.
Check C
Compressor
Damage
Check C
Replace
Capacitor
Replace
Compressor
N
N
Reset
Power
Stroke Trip
Occur?
Y
Repeat
Check Procedure
Harness
Connecting
Check C
Fix Harness
N
N
Cycle
Check E
Fix
Cycle
Replace
Driver PCB
OK
NG
- Purpose: Prevent abnormally long piston strokes.
- Case 1. If compressor doesn’t work and LED blinks - Cause: Possibly harness from compressor to PCB might be
defective.
- Case 2. If compressor works intermittently and LED blinks - Cause: Condenser Fan or Freezer Fan is not running. Sealed
system problem such as moisture restriction, restriction at capillary tube or refrigerant leak.
- Logic: Compressor is forced to off and then tries to restart after 1 minute.
GND
Voltage
※
Caution : Devices should not be short-circuited durng check C
Summary of Contents for LFXS30786 Series
Page 4: ... 4 2 PARTS IDENTIFICATION Ice Bin Icemaker Ice Compartment Door ...
Page 7: ... 7 ...
Page 25: ... 25 5 CIRCUIT DIAGRAM ...
Page 26: ... 26 6 TROUBLESHOOTING ...
Page 27: ... 27 ...
Page 29: ... 29 7 3 Sub PCB ...
Page 107: ... 107 13 DESCRIPTION OF FUNCTION CIRCUIT OF MICOM ...
Page 108: ... 108 ...