After measure the values, you should put in the TPA again.
9. TEST MODE and Removing TPA
1. How to make TEST MODE
If you push the test button on the Main PCB, the refrigerator will be enter the TEST MODE.
2. How to remove Terminal Position Assurance (TPA)
* 1 time : Comp / Damper / All FAN on
(All things displayed)
* 2 times : Damper closed
(22 22 displayed)
* 3 times : Forced defrost mode
(33 33 displayed)
Main PCB
<AC TPA>
<DC TPA>