- 40 -
Symptom
Check Point
1. F dH
1. Check the door gasket
2. Check the defrost control parts
3. Check the PCB output voltage
4. Check defrost heater
Defrost Control Parts
CON3
Defrost
Heater #1
Fuse-M
Defrost
Sensor
Defrost
Heater #2
Part
Resistance [Ω]
FUSE-M
0.2 ↓
Defrost Heater
(1) 225~ 260
(2) 525 ~ 615
Total Heater
Resistance
150 ~ 180
Defrost Sensor
22k↑
TEST MODE 3
Voltage [V]
CON3
3
rd
- 10
th
pin
210 ~ 230
TEST MODE 1
Voltage [V]
CON3
3
rd
- 10
th
pin
0V
CON7
CN1
CON6
CON5
CON3
CON2
CON1
CON201
8-6. Defrost Heater Error (F dH)