![LG LFXS30726 Service Manual Download Page 60](http://html.mh-extra.com/html/lg/lfxs30726/lfxs30726_service-manual_1903298060.webp)
- 60 -
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
Symptom
Check Point
1. Poor cooling in Fresh
food section
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4. Check the R-Fan motor voltage
CON6
CON7
13
th
pin ~ 14
th
pin
Resistance [Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Duct
Status
Air Flow
Windy
Air Temperature
Cold
CON7
TEST MODE 1
Voltage [V]
CON6
3
rd
pin ~ 5
th
pin
8~12V
CON6
1
st
pin ~ 5
th
pin
Not 0V, 5V
Duct
8-18. Poor cooling in Fresh food section