- 46 -
TEST MODE 1
Voltage [V]
CON7
2
th
pin ~6
th
pin
Not 0V, 5V
Condenser Fan Error (E CF)
1
2
Check the fan rotating.
Does fan rotate?
No
Yes
Go to 3
4
Check the Fan Motor voltage
Is Fan Motor voltage 8~12V?
Yes
3
Check the Fan motor.
Rotate fan using hand.
It feel sticky?
Yes
Change the
Fan motor
Replace
Main PCB
No
Reset the unit and
Input Test1 Mode.
(Push the button 1 time)
Go to 4
TEST MODE 1
Voltage [V]
CON7
4
th
pin ~6
th
pin
8~12V
5
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V, 5V?
No
Change the
motor
Yes
6
Explain to customer
Summary of Contents for LFXS30726
Page 7: ... 7 ...
Page 20: ... 20 5 CIRCUIT DIAGRAM ...
Page 21: ... 21 6 TROUBLESHOOTING ...
Page 22: ... 22 ...
Page 24: ... 24 7 3 Sub PCB ...
Page 98: ... 98 13 DESCRIPTION OF FUNCTION CIRCUIT OF MICOM ...
Page 99: ... 99 ...