- 29 -
Symptom
Check Point
1. E IS
1. Check for a loose connection
2. Check Sensor Resistance
Resistance [Ω]
CON5
11
th
pin ~ 12
th
pin
Short
0
Open
OFF
Other
Normal
CON5
11
th
pin ~ 12
th
pin
Resistance [Ω]
-22ºF / -30ºC
40k
-13ºF / -25ºC
30k
-4ºF / -20ºC
23k
-13ºF / -25ºC
17k
14ºF / -10ºC
13k
23ºF / -5ºC
10k
32ºF / 0ºC
8k
CON5
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
8-3. Icing Sensor Error (E IS)