2.1 Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.
If the appliance is hooked-up to the supply by means of a fixed
connection, install a multipolar cut-out device on the line, with
contact opening distance equal to or greater than
3 mm
, located
near the appliance and in an easily reachable position.
Hook-up to the supply may be fixed or with plug and socket. In the
latter case the plug and socket must be suitable for the cable
employed and conform with the regulations in force. Regardless of
the type of connection, earthing of the appliance is absolutely
obligatory. Before connection make sure that the supply line is
suitably earthed. Avoid the use of reducers, adapters or shunts.1
If the power cable is replaced, the wire
section on the new cable must not be less
than 1.5 mm2 (3 x 1.5 cable), keeping in
mind that the end to be connected to the
hob must have the ground wire (yellow-
green) longer by at least 20 mm. Use only H05V2V2-F cable or
similar which has a maximum temperature of 90°C. This must be
done by a specialised technician, who must connect the cooker to
the electricity supply according to the diagram shown here.
L
= brown
N
= blue
= yellow-green.
Warning:
The values indicated above refer to the cross-section
of the internal conductor.