Operation and settings
13
PTZ protocol (Option)
Allows the user to configure different PTZ controls by using different
PTZ protocols.
PTZ protocol list
>
PTZ protocol: Displays the selected PTZ protocol.
>
Edit: Click to display the PTZ protocol window. Select the PTZ
protocol and then click the [Save] button. If you want to delete
the protocol, click the [Remove] button.
Upload PTZ protocol
Follow the instructions below to upload PTZ protocol.
1. Click the [Browse] button, find and open the file and then click
[Upload] button.
2. Click the [Add PTZ protocol] button and then the PTZ protocol
will be added.
PTZ configuration
>
Enable: Click to use the PTZ protocol.
>
Camera ID: Enter the PTZ device ID. Make the same ID as the
PTZ Device.
>
Pan speed: Enter the panning speed of the PTZ device in the
edit box. Default value for the LG Multix Protocol is 60 and
ranges from 0 to 127.
>
Tilt speed: Enter the tilting speed of the PTZ device in the edit
box. Default value for the LG Multix Protocol is 60 and ranges
from 0 to 127.
>
Zoom speed: Enter the zoom speed of the PTZ device to view
the object close or at a distance. Default value for the LG Multix
protocol is 1 and ranges from 0 to 3.
>
Focus speed: Enter the focus speed of the PTZ device to focus
an object clearly near or far. Default value for the LG Multix
protocol is 1 and ranges from 1 to 3.
>
Preset tour park time: Enter the parking time.
Port
>
Baud rate: Select the desired speed of communication
between the IP device and the PTZ Device. Confirm selected
parameter to the baud rate of the IP device.
>
Data bit: Set the number of the data bits for RS-422/RS-485
communication.
>
Parity: Select the desired parameter. The parity bit, added to the
data, to perform parity check.
>
Stop bit: Enter the desired parameter. The stop bit, added to
the last of data, in asynchronous communication.
•
Save: Click this button to confirm the settings.
Summary of Contents for LDW2010 series
Page 67: ......