- 24 -
B. STEAM GENERATOR ERROR MESSAGE
The normal condition
The generator heater temperature
is high. (over 239
)
The water leveling sensor is working
abnormally.
Not reached to the normal water
level.
The generator heater temperature
is low. (lower than 158
)
The normal condition
Check the water level sensor and
thermistor check.
Check the wiring connection and
water level sensor.
Check the inlet valve and sensor
connection.
Check the heater and thermistor.
00 : E0
00 : E1
00 : E2
00 : E3
00 : E4
00 : E5
ERROR MESSAGE
CONDITION
REMEDY
Steam Generator Error mode is not displayed in normal condition and it can be confirmed
by following additional operation.
To confirm steam generator error, press the
DELAY START
and
RINSE ONLY
buttons
simultaneously.
When Steam Generator is out of order, dishwasher operates the selected cycle without
steam.
MFL37554808(S/M) 2009.2.5 8:54 AM
˘
` 24 ‰¯¿
ł
– •¡
˙
¨‰”