For Authorized Service Technician
- 28 -
7. TROUBLE SHOOTING METHODS
Inlet Error
Condition.
Not reached to the normal water level
in spite of 10 min. water supply.
The water is supplied.
Frequency is not increased
The water is not
supplied.
Is the water tap opened?
Open the water tap.
Repair the inlet hose.
Install the pressure pump.
a) Close the water tap.
b) Unscrew the inlet hose.
(Inlet valve side)
c) Clean the filter of inlet valve.
Is the inlet hose kinked?
Is the water pressure
very low or high?
(below 0.5kgf/
㎠
(20bar),
above12kgf/
㎠
(120bar))
Is the filter of inlet valve
clogged by impure water?
Does the water supplied?
Check the frequency of Inlet Water by
the Test Mode.
Is the connector connected to
main PCB assembly disconnected
or disassembled? (NA8)
Is the voltage between connectors
out of range? (NA8 pin1 ~ pin2)
- After remove terminal position
assurance (TPA) of connector,
check the voltage when water is injected.
(The voltage is 2.5V AC (±15%)
Is the resistance vales between
connectors out of range?
(range is over 5MΩ)
(White 8P, Pin1~Pin2)
Reconnect or
repair the connector.
Replace the main
PCB assembly
Is the Inlet sensor operate properly?
Blue 6P 1-2 is 12V
Replace the inlet valve
Inlet Valve 25±5% (Ω)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
Is displayed?