4-7
Components
Test procedures
Results
Triple surface unit :
Right Front (RF)
Element
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the (1 & 2A)
and (4 & 2A) and (3 & 2A) the meter should
indicate :
- (1 & 2A)
52 Ω ± 10%
- (4 & 2A)
49 Ω ± 10%
- (3 & 2A)
68 Ω ± 10%
Normal : Approximately 52 Ω
Normal : Approximately 49 Ω
Normal : Approximately 68 Ω
1 4
2A
3
5. Touch the ohmmeter test leads to limiter terminal
1B and 2B. With the temperature below 150℉, the
meter should indicate an open circuit (infinite)
With the temperature above 150℉, the meter
should indicate continuity (0 Ω)
Below 150˚F
open circuit(infinite).
Above 150˚F
continuity (0 Ω)
2B
1B
Summary of Contents for LDE4415BD
Page 57: ...5 3 Touch PCB P N EBREBR79627601 P N EBR78789101 P N EBR76332902 NFC and Buzzer PCB ...
Page 60: ...5 6 Touch PCB P N EBREBR79627601 P N EBR83227505 P N EBR76332902 Wi Fi and Buzzer PCB ...
Page 88: ...8 3 LOWER BAKE CONV BAKE CONV ROAST LOWER BROIL ...
Page 89: ...8 4 UPPER SELFCLEAN LOWER SELFCLEAN ...
Page 90: ...8 5 OVEN LAMP CLOCK DISPLAY ON ...
Page 91: ...8 6 CR Cooktop element LR RR Cooktop element ...
Page 92: ...8 7 LF Cooktop element RF Cooktop element ...
Page 98: ... EV COOKTOP PARTS 3056 3402 3099 3059 330S 330S 3022 330M 330H 3006 3204 3016 301C ...
Page 101: ......