A. TROUBLE SHOOTING ACCORDING TO DISPLAYED ERROR MESSAGE
ERROR MESSAGE
POSSIBLE CAUSE
REMEDY
FOR ERROR OCCURRENCE
The Water Tap is not opened.
The Inlet Hose is kinked.
The Filter of inlet valve clogged
by impure water.
The Inlet Water Valve is normal ?
The water pressure is very low.
( below 0.5 kgf/
)
Inlet valve is blocked by safety
device for leakage sensing.
The Filter clogged.
The Drain Hose kinked or blocked.
The Drain Pump/Motor or circuit is
troubled.
Water leakage in Hose connections.
Water is leaked by damages.
Clean the Filter.
Remove the cause of kink or block.
Replace the Drain Pump/Motor or
repair the Circuit.
Replace the connections of Hose.
Check the point of damages and
repair or replace the related parts.
Open the Water Tap.
Repair the Inlet Hose.
a) Close the Water Tap.
b) Unscrew the Inlet Hose (Inlet Valve side)
c) Clean the Filter of Inlet Valve.
Replace or repair the Inlet Valve.
Check the water remain on the base.
1) Check the point of damages and
repair or replace the related parts.
2) Disconnect the inlet hose to
dishwasher to unlock the safety valve.
Not reached to the nor-
mal water level in spite
of 10 min. water supply
INLET ERROR
displayed
Condition
Not fully drained out in
spite of 5 min. drain
operation
The water level in Tub
goes down during
operation
DRAIN ERROR
displayed
Condition
LEAKAGE ERROR
displayed
Condition
- 27 -
8.TROUBLE SHOOTING METHODS
Summary of Contents for LD-14AT2
Page 12: ... 13 5 WIRING DIAGRAM LD 4050W ...
Page 13: ...5 WIRING DIAGRAM 14 LD 14AW2 LD 14AT2 ...
Page 14: ... 15 6 PROGRAM CHART SCHEMATIC DIAGRAM ...
Page 15: ...6 PROGRAM CHART PGM TIME Flow Default Vario 16 ...
Page 37: ...10 EXPLODED VIEW 38 LD 4050W LD 14AT2 LD 14AW2 ...
Page 46: ...10 EXPLODED VIEW 47 LD 14AT3 LD 14AW3 ...
Page 53: ...P No 3828ED3001L ...