- 22 -
5) synchronous motor
Remove the 2 screws.
Lift the cam upward.
Be careful not to install upside down.
(part number on the cam should face the
motor.)
6) Vario valve
Remove 4 screws and lift the cover
upward.
Lift the vario valve upward.
7) Capacitor
Remove 1 screw.
8) Inlet valve
Remove 2 screws.
Summary of Contents for LD-14AT2
Page 12: ... 13 5 WIRING DIAGRAM LD 4050W ...
Page 13: ...5 WIRING DIAGRAM 14 LD 14AW2 LD 14AT2 ...
Page 14: ... 15 6 PROGRAM CHART SCHEMATIC DIAGRAM ...
Page 15: ...6 PROGRAM CHART PGM TIME Flow Default Vario 16 ...
Page 37: ...10 EXPLODED VIEW 38 LD 4050W LD 14AT2 LD 14AW2 ...
Page 46: ...10 EXPLODED VIEW 47 LD 14AT3 LD 14AW3 ...
Page 53: ...P No 3828ED3001L ...