4
"
30"~60"
Awning
Cooled air
Fence
Over 20"
Heat
radiation
21" min.
40
1
/
2
" max.
15
1
/
2
"
min.
21
1
/
2
" min.
15
1
/
2
" min.
16
1
/
2
" max.
Horizontal sliding window
Casement window
10
Hardware Installation
Hardware
Installation
Remote Control Operations
How to Install the Unit
How to Install the Unit
Remote Control Operations
How to Install the Unit
Window Requirements
1. To prevent vibration and noise, make sure the unit is
installed securely and firmly
2. Install the unit where the sunlight does not shine directly
on the unit.
3. The outside of the cabinet must extend outward for at
least 14" and there should be no obstacles, such as a
fence or wall, within 20" from the back of the cabinet
because it will prevent heat radiation of the condenser.
Restriction of outside air will greatly reduce the cooling
efficiency of the air conditioner.
CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.xz
4. Install the unit at a slight incline so the back is slightly lower than the front(about 1/4").
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 30"~60" above the floor level.
1. These instructions are for a horizontal sliding or a
casement window.
2. The electrical outlet must be within reach of the
power cord.
For installation in a casement window, the window
frame assembly and the side of the building must be
adequate to support the weight of the air conditioner.
Summary of Contents for LC1000