32 Multi Air Conditioner
Operation Details
■
Auto Restarting Operation
• When the power is restored after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• The slide switch on the main unit of the appliance should be on the Auto Restarting position in order that the
Auto Restarting operation is available.
• Operation Mode that is kept on the memory
- State of Operation ON/OFF
- Operation Mode/Setting Temp/Selected Airflow Speed
- Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour)
Slide Switch
FORCED
OPERATION
AUTO
RESTART
REMOTE
CONTROL
■
Forced Operation (C/O Model)
• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• When the power is supplied while the slide switch is on the forced operation position, or when the slide switch
position is switched to the Auto Restarting position (or test operation) or switched from the remote control posi-
tion to the forced operation position while the power is on, the forced operation is carried out.
• When the slide switch position is switched from the forced operation position to the Auto Restarting position or
the remote control position, the forced operation is canceled and the appliance stops operating.
• The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of
airflow.
• While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to
indicate the forced operation.
■
Forced Operation (H/P Model)
• To operate the appliance by force in case that the remote control is lost, the forced operation selection switch
is on the main unit of the appliance to operate the appliance in the standard conditions.
• When the power is supplied while the slide switch is on the forced operation position, or when the slide switch
position is switched to the Auto Restarting (or test operation) position or switched from the remote control posi-
tion to the forced operation position while the power is on, the forced operation is carried out.
• When the slide switch position is switched from the forced operation position to the Auto Restarting position or
the remote control position, the forced operation is canceled and the appliance stops operating.
• The forced operation is carried out in cooling mode with the setting temperature 22°C and the high speed of airflow.
• In the forced operation mode, the indoor fan is operated at low speed for around 15 sec and then the operation
condition is set according to the intake air temperature as follows.
24°C
≤
Intake Air Temp
➲
Cooling Mode Operation, 22°C, High Speed
21°C
≤
Intake Air Temp<24°C
➲
Dehumidification Operation, 23°C, High Speed
Intake Air Temp<21°C
➲
Heating Mode Operation, 24°C, High Speed
• While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to
indicate the forced operation.
Summary of Contents for L2-C242GL0
Page 13: ...Service Manual 13 Dimensions 900 1 225 370 L3 C482LL0 ...
Page 19: ...Service Manual 19 Electronic Control Device Display P C B ASM ...
Page 21: ...Service Manual 21 Schematic Diagram L2 C362LL0 ...
Page 22: ...22 Multi Air Conditioner Schematic Diagram Outdoor Unit L3 C362LL0 ...
Page 23: ...Service Manual 23 Schematic Diagram L3 C482LL0 ...
Page 75: ...P No 3828A20156P January 2005 Printed in Korea ...