Read completely, then follow step by step.
6
Indoor Unit
Installation
Installation
Selection of the best location
There should not be any heat source or steam near the unit.
There should not be any obstacles to the air circulation.
A place where air circulation in the room will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
The indoor unit must have the maintenance space.
Ceiling
Ceiling Board
Ceiling Board
Floor
Unit:mm(inch)
300(11-
13
/
16
)
or more
Abo
ve 2500(98-
7
/
16
)
4000(157-
1
/
2
) or less
1000(39-
3
/
8
)
or more
500(19-
11
/
16
)
or more
500(19-
11
/
16
)
or more
300(11-
13
/
16
) or less
CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.