88
B. Check ALPC Parameters
1. Select About on the menu bar.
2. Click Addition Func. on About window -> New frame will be displayed.
3. Click ALPC Para tab and verify the specification.
[ALPC Parameters]
1) CD VRDC
: 117~153
2) CD VWDC_NMP
: 100~135
3) CD VWDC_MP
: 100~137
4) CD VWDC_ERASE
: 105~135
5) DVD VRDC
: 115~157
6) DVD VWDC_NMP
: 100~135
7) DVD VWDC_MP
: 100~135
8) DVD VWDC_ERASE
: 105~140
9) H.C. VWDC
: 100~150
10) Default ALPC Para. used
: 0xFF
4. Close window.