(2) Load Operation in Failure
- 13 -
Classification
ITEM
NO
UPPER
COMPARTMENT
FAN
COMP
DEFROSTING
HEATER OF
UPPER
COMPARTMENT
DEFROSTING
HEATER OF
MIDDLE
COMPARTMENT
STEPPING
MOTOR
DAMPER
SINGLE
MOTOR
DAMPER
3-WAY
VALVE
FRONT-C
HEATER
MIDDLE
COMPARTMENT
FAN
Normal
Failure of
Upper
compartment
(K1) sensor
Failure of
Middle
compartment
(K1) sensor
Failure of
Upper
compartment
(K1) sensor
Failure of
Upper
compartment
defrosting
sensor
Failure of
Middle
compartment
defrosting
sensor
Failure of
ambient
Temperature
sensor
Poor
defrosting
at upper
compartment
Poor
defrosting
at middle
compartment
Failure of
single
motor
damper
Poor
communication
1
2
3
4
5
6
7
8
9
10
11
O
15 min
ON/
15 min
OFF
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Don’t
defrost
(immediat
ely return)
O
O
O
O
O
O
O
O
O
O
O
Don’t
defrost
(immediat
ely return)
O
O
O
O
O
O
O
15 min
OPEN/
15 min
CLOSE
O
O
O
(No
compensation
of ambient
temperature)
O
O
O
O
O
O
O
10 min
OPEN/
15 min
CLOSE
O
O
(No
compensation
of ambient
temperature)
O
O
Perform
normal
initialization
by checking
operation
in the cycle
of 1 hour
O
O
O
(Linked
with
COMP.
However,
FRONT-C
heater
turns off
for 15
minutes
and turn
on again if
the heater
turn on
time
continues
for more
than 40
minutes)
Summary of Contents for GR-J303TG
Page 5: ...2 CIRCUIT DIAGRAM 5 ...
Page 28: ... 2 Parts List 28 ...
Page 29: ... 29 SRT ASSEM ...
Page 30: ...3 4 2 PWB PCB ASSEMBLY DISPLAY STANDARD 1 Parts diagram 30 2 Parts List ...
Page 32: ... 32 LCD 6871JB1464 LED 6871JB1465 ...
Page 33: ...3 5 2 PWB PCB ASSEMBLY DISPLAY CIRCUIT DIAGRAM 33 LCD 6871JB1464 LED 6871JB1465 ...
Page 38: ... 38 u u GR J303TG TS 252A 252C 128B 252B 252A 252C 252B 253A 253C 253B ...