- 10 -
3-1-7. FRONT-C HEATER CONTROL
1. A heater for prevention of dewing is installed on the FRONT-C part between the middle compartment and the lower
compartment, and turns on at the time of COMP ON and for 20 minutes after COMP OFF.
2. It turns off in the test mode (turn on after power off for normal operation).
3-1-8. BUZZER RINGING
1. “Ding~Dong~” sound rings when pressing the front display button.
2. No buzzer rings if pressing the button not according to the operation order.
3-1-9. POWER FAILURE COMPENSATION FUNCTION
1. Previous operation is performs even applying power again after power failure. However, error status or test mode status
is excluded.
3-1-10. OPERATION RESPOND TO AMBIENT TEMPERATURE
1. This is function of maintaining keeping temperature constantly irrespective of season by compensating for the in-
refrigerator temperature through ambient temperature of the refrigerator to prevent that the in-refrigerator temperature
changes according to ambient temperature (weak cold in winter, excess cold in summer).
3-1-11. DEFROSTING (REMOVAL OF FROST)
1. Defrosting is simultaneously performed by using the defrosting heater at the upper compartment and the middle
compartment whenever sum of compressor operation time reaches to 6 hours.
2. Defrosting is started if sum of compressor operation time reaches to 4 hours in input of initial power (or in returning from
power failure).
3. Complete defrosting function where defrosting sensor temperature of each room reaches to 7°C (16°C for GR-J213) for
the upper compartment, 16°C for the middle compartment respectively, after starting defrost work.
However, poor defrost is indicated if not reaching to 7°C (16°C for GR-J213) for the upper compartment, 16°C for the
middle compartment respectively 2 hours after starting defrost (See 3-1-11 Failure Diagnosis Function).
4. Poor defrost is indicated if the defrosting sensor is poor, and defrosting of the relevant room is not done.
-1.5
°
C
-0.5
°
C
4.0
°
C
Keeping Temperature
(based on “Mid”)
Season
Spring
Summer
Fall
Winter
Operation Respond to Ambient Temperature
In General Operation
Summary of Contents for GR-J303TG
Page 5: ...2 CIRCUIT DIAGRAM 5 ...
Page 28: ... 2 Parts List 28 ...
Page 29: ... 29 SRT ASSEM ...
Page 30: ...3 4 2 PWB PCB ASSEMBLY DISPLAY STANDARD 1 Parts diagram 30 2 Parts List ...
Page 32: ... 32 LCD 6871JB1464 LED 6871JB1465 ...
Page 33: ...3 5 2 PWB PCB ASSEMBLY DISPLAY CIRCUIT DIAGRAM 33 LCD 6871JB1464 LED 6871JB1465 ...
Page 38: ... 38 u u GR J303TG TS 252A 252C 128B 252B 252A 252C 252B 253A 253C 253B ...