This device is to be serviced only by properly qualified service personnel.
Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be
taken to avoid possible exposure to excessive microwave energy.
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
A) Do not operate or allow the oven to be operated with the door open.
B) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary; (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.
C) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
D) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual
before the oven is released to the owner.
E) A microwave leakage check to verify compliance with the CSA Standard should be performed on each
oven prior to release to the owner.
SAFETY PRECAUTIONS
Summary of Contents for GoldStar MA-1302S
Page 30: ...6 2 13581A 13720D 13213A 13552A 15006A 13536A 14890A 14026A 14970A WTT040 13650A DOOR PARTS ...
Page 31: ...6 3 24781S 23806C 23572A 268712 268711 249401 250201 CONTROL PANEL PARTS ...
Page 33: ...6 5 WSZ085 43501A 466001 466003 466001 43500A LARCH BOARD PARTS ...
Page 34: ...6 6 54974T 55900A 50CZZH 54810C WSZ002 WSZ002 WTT037 56549F 54974S 56201A SUCTION GUIDE PARTS ...
Page 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 38: ...8 2 PRINTED CIRCUIT BOARD ...