5-9
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
¥ Primary winding
¥ Secondary winding
¥ Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Primary winding to ground
¥ Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
¥ Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
¥ Filament to chassis
Approx.: 0.2 ~ 0.4 ohm
Approx.: 60 ~ 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
COMPONENT TEST PROCEDURE
Summary of Contents for GoldStar MA-1302S
Page 30: ...6 2 13581A 13720D 13213A 13552A 15006A 13536A 14890A 14026A 14970A WTT040 13650A DOOR PARTS ...
Page 31: ...6 3 24781S 23806C 23572A 268712 268711 249401 250201 CONTROL PANEL PARTS ...
Page 33: ...6 5 WSZ085 43501A 466001 466003 466001 43500A LARCH BOARD PARTS ...
Page 34: ...6 6 54974T 55900A 50CZZH 54810C WSZ002 WSZ002 WTT037 56549F 54974S 56201A SUCTION GUIDE PARTS ...
Page 37: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 38: ...8 2 PRINTED CIRCUIT BOARD ...