49
ENGLISH
ERROR MODE / POWER FAIL RECOVERY / DEFAULT DRYER SETTINGS
PROBLEM
POSSIBLE CAUSE
SOLUTION
It is displayed when thermistor is opened or
shorted
Thermistor should be replaced.
ELECTRIC TYPE
It is displayed when thermistor temperature
have increased about 5 degrees for 3 seconds
GAS TYPE
It is displayed when thermistor temperature
have increased about 17 degrees for 10
seconds
Thermistor should be replaced.
Disconnection of card reader wire.
Check the card reader wire.
ERROR MODE
Meaning of Error Codes that LED displays during occurrence or
problem.
Dryer error code
POWER FAIL RECOVERY
In case of power failure the machine stops running but the time display remains on, showing the time just before
power failure.
Press the
START
button after the power is restored, then the machine will restart.
DEFAULT DRYER SETTINGS
Default Settings
Default
Cycle Time (Minutes)
45 Minutes
Cool Down Time Cycle
2 Minutes
High Temperature
154.4° F (68° C)
Medium Temperature
140° F (60° C)
Low Temperature
ELECTRIC TYPE 125.6° F (52° C)
GAS TYPE 116.6° F (47° C)
Top Off Time (Minutes per coin)
5 Minutes
Coin #1 Value
0.25
Coin #2 Value
0.25
Minutes/Minutes and seconds
Minutes
Fahrenheit/Celsius
Fahrenheit
Error Mode
On
• Price setting varies by country.
• Set your country from
mode. (Refer How to enter the
)
• After EEPT, reset your country. (Default country is ELC)
NOTE
MFL67863711_en_170328.indd 49
2017-03-28 �� 10:12:29