LD Check
Focus Servo is unstable
Go to “LD Control is abnormal”.
OK
OK
NG
NG
OK
NG
OK
OK
OK
After Power On, does Pick
up move
Check Dumping Reg.
RA102, RA103.
1)Check Soldering of IC101.
2) Check voltage of 5V.
3) Check voltage of Vhalf.
1) Check Soldering of PG101.
2) Check voltage of TL331(5V).
3) Check voltage of TL327(2.2V).
4) Check insertion or damage of Main
FPC.
1)Check Soldering of PG101.
2) Check voltage of TL311(5V).
3) Check voltage of TL313(Vhalf).
4) Check insertion or damage of
Main FPC.
Is Pick Up
Signal normal?
PG101(22, 23, 25~30)
Go to Focus Drive check.
Replace IC101.
Is Focus Drvie normal?
TL316.
Replace Unit Mecha and
Execute LD Calibration.
OK
NG
OK
Is Focus Drive normal?
IC201 (178)
NG
Check LPF (R250, C250).
Replace IC201.
OK
Replace Unit Mecha and Execute LD
Calibration.
Focus Error Check.
Focus Drive Check.