When measuring power, be sure to wear insulated gloves, to avoid electric shock.
While operating, heating will not work.
Drying time takes longer
With dryer power on
Power on & start (Normal cycle)
When measuring Valve 1 voltage,
More than DC 90V?
Igniter operates?
(after 1 min, igniter becomes reddish)
When measuring Valve 2 voltage, value is more
than DC 90V? (10 sec after Igniter off)
When measuring terminal resistance on valve 1 and
valve 2, valves are more than1.5 ~ 2.5k
?
(Measure after off )
If valve 1 and valve 2 are under DC 10V, valves
are Off?
Harness check
Controller change
Check thermostat
hi-limit safety
Check Igniter &
frame detect
Check gas
connection or
gas supply
Change valve
Change valve
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
Valve 1
NOTE:
When the gas valve operates after disassembling, ignition will be off several seconds.
It is normal because there is no circulation of air
Caution
Trouble Symptom
Measurement Condition
Valve 2
Igniter
26
Test 7
GAS Valve test - Gas Type
Summary of Contents for DLEY1701
Page 8: ......
Page 9: ......
Page 15: ...7 WIRING DIAGRAM 15 ...
Page 17: ......
Page 18: ...18 8 3 Troubleshooting for flow sensor dryer ...
Page 25: ...25 Test 6 Heater switch test Electric Type Caution Trouble Symptom Measurement Condition ...
Page 28: ...28 GAS VALVE FLOW V A LVE 1 IGNITER V A LVE 2 FLAME DETECT NO NO YES YES 374 190 ...
Page 36: ...36 ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 43: ...43 ...
Page 47: ...13 1 Door 13 SCREW POSITION 47 ...
Page 48: ...13 2 Cabinet Cover 48 ...
Page 49: ...14 Tag On 49 ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 Laundry Status Run Cycle Again Using LG Smart Laundry DW application ...
Page 55: ...55 ...
Page 58: ...58 15 2 1 Cabinet Door Assembly Electric Type A600 A800 A700 A545 A500 A520 A540 A510 A131 ...
Page 59: ...59 15 2 2 Cabinet Door Assembly Gas Type A550 A800 A700 A545 A500 A520 A540 A510 A131 ...