13
13. Outlet Thermostat
(Auto reset)
14. Outlet Thermostatt
(Manual reset)
Measure resistance of terminal
to terminal
Open at 203
7 F (95
5 C
Close at 159
9 F (70
5 C)
Gas type
Gas funnel
Gas type
Electric type
Gas funnel
Measure resistance of terminal
to terminal
Open at 212
12 F
(110
7 C)
Manual reset
If thermal fuse is open must
be replaced
Resistance value
Continuity <
1
Ω
·
Check Top Marking:
N95
·
Check Top Marking:
N110
Resistance value
Continuity <
1
Ω
Component Test Procedure Check result
Remark
15. Inlet. valve
Measure resistance of the
Following terminal
Left picture
-.plate
Summary of Contents for DLEY1701
Page 8: ......
Page 9: ......
Page 15: ...7 WIRING DIAGRAM 15 ...
Page 17: ......
Page 18: ...18 8 3 Troubleshooting for flow sensor dryer ...
Page 25: ...25 Test 6 Heater switch test Electric Type Caution Trouble Symptom Measurement Condition ...
Page 28: ...28 GAS VALVE FLOW V A LVE 1 IGNITER V A LVE 2 FLAME DETECT NO NO YES YES 374 190 ...
Page 36: ...36 ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 43: ...43 ...
Page 47: ...13 1 Door 13 SCREW POSITION 47 ...
Page 48: ...13 2 Cabinet Cover 48 ...
Page 49: ...14 Tag On 49 ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 Laundry Status Run Cycle Again Using LG Smart Laundry DW application ...
Page 55: ...55 ...
Page 58: ...58 15 2 1 Cabinet Door Assembly Electric Type A600 A800 A700 A545 A500 A520 A540 A510 A131 ...
Page 59: ...59 15 2 2 Cabinet Door Assembly Gas Type A550 A800 A700 A545 A500 A520 A540 A510 A131 ...