23
3. Status Mode Of wrong Connection
1.Black and White Housing
2.Black Housing
3.White Housing
❇
4.Black and White Housing
5.Black and White Housing
Off
Off
Normal
Heater2
Off
Off
Off
Normal
Heater1
Off
Power Off
Power Off
Power On
Power On
Power Off
Wire
①
,
②
CROSS
Wire
①
,
②
CROSS
Wire
①
,
②
CROSS
Housing CROSS
Housing and Wire
①
,
②
CROSS
Items
Case
Heater1
Operation(black)
Heater2
operation(White)
PCB condition
Of operation
1.Black and White Housing
Off
Off
Power Off
Wire
①
,
②
CROSS
Items
Case
Heater1
Operation(black)
Heater2
operation(White)
PCB condition
Of operation
- In case of power failure(<Table1>-1,2,5,<Table2>-1), Please check the Connection of “2.Status Table of Connection”.
In case of power failure(<Table1>-4), please check the Connection of “2. Status Table of Connection”. Because improper
Connection of the equipment-dryer can be damaged of changing heater.
!
CAUTION
Connector Housing
Black
Check the Matching color Between
Harness wire and Tab Relay.
(Black Housing
–
Black Tab Relay)
Color
< Table 2 > : Connection of Tab Relay with PCB ASSEMBLY (Gas)
< Table1 > : Wrong Connection of the Tab Relay and Connector Housing (Elec)
< Table2 > : Wrong Connection of the Tab Relay and Connector Housing (Gas)
Harness
Remark
PCB
Tap relay 1
1
2
Blue Wire
Black Wire
Connector Housing