20
ACTIVATING THE DIAGNOSTIC TEST MODE
1. Unit must be in Standby (unit plugged in, display off)
2. Press
POWER
while pressing
MORE TIME
, and
LESS TIME
simultaneously.
DIAGNOSTIC TEST
9
Pressing the
START/PAUSE
button
CHECKING
ACTION
DISPLAY
CHECKING POINT
REMARK
None
Once
Electric control
&
Temperature
sensor
Motor
Won
’
t power up
Detective LED or LCD
LQC TEST
tE1
tE2
Thermistor open
Thermistor close
Motor runs
Displays Moisture Sensor Operation:
If moisture sensor is contacted with
damp cloth. The display number is
below 180, in normal condition.
70 ~ 239
Measured
Moisture Value.
Twice
■
ELECTRIC TYPE
Motor + Heater 1 (2700W)
■
GAS TYPE
Motor + Valve
Current Temp.
■
ELECTRIC TYPE: Heater runs
■
GAS TYPE: GAS Valve runs
(Display the Temperature of
Inside drum.)
During check,
If the door is closed.
Motor on & Heater
Off + Lamp Off
70 ~ 239
•
Press Start button 1 time and then open the
door. Proceed again with the step 1 (by pressing
start 1 time), step 2 (by pressing start 2 times),
step 3 (by pressing start 3 times) and step 4 (by
pressing start 4 times) in sequence.
•
Press Start 2 times and then open the door. Proceed
again from the step 1 all the way to the step 4.
•
Press Start 3 times and then open the door
Proceed with the step 1 and skip the step 2 and
press step 3 twice and finish with step 4 by
making sure the all the electric devices shut off
in the end.
4 times
5 times
Motor, Heater
Control Off
Motor, Heater Off
Auto Off
3 times
■
ELECTRIC TYPE
Motor + Heater 1
+Heater 2 (5400W)
■
GAS TYPE
Motor+Valve
Current Temp.
(5 ~ 70)
50~230 Measured
“
dE
”
or
“
Error
”
(THE DOOR IS
OPEN.PLEASE CLOSE THE
DOOR COMPLETELY)
During check,
If the door is open.
Motor & Heater Off + Lamp On +
Buzzer beeps seven times
Door switch
See test 6
Lamp
See test 1
Display: See page
See test 2
See test 3
See test 4
Gas valve
See test 7
1. This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not activate it
manually. (Do not press the door switch to operate the heater while the door is open )