DIAGNOSTIC TEST
20
1.This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than specified.
2.Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do not
activate it manually. (Do not press the door switch to operate the heater while the door is open )
To check pump operation:
At the fourth press of the test mode, if the AD value of the pump is higher than 10 on the display, the pump is normal.
If it is lower than 10, E5 error will be displayed.
Pressing the
START/PAUSE
None
Standard
DISPLAY PGM
d-
MAIN PGM
U-
L04(Elec Type)
L05(Gas Type)
Thermistor open
tE
Thermistor shorted
Power off
Motor runs
Displays Moisture Sensor Operation
If moisture sensor is contacted with
damp cloth. The display number is
below180 in normal condition.
235 = Low
moisture
30 = High
moisture
Current Temp.
(5~70)
Current Temp.
(5~70)
Electric control
&
Temperature sensor
ELECTRIC TYPE
Motor+Heater1(2700 W)
GAS TYPE
Motor
ELECTRIC TYPE
Motor+Heater2
(5400W)
GAS TYPE
Motor+Gas valve
Once
Motor+Controller
Steam off
Loads off, Controller off
Twice
3 times
5 times
Motor, Heater off, Steam on
4 times
6 times
CHECKING
ACTION
DISPLAY
CHECKPOINT
ELECTRIC TYPE Heater 1 is
energized - 2700 W
GAS TYPE Valve not energized
(Temperature in the drum is
displayed in degrees C.)
ELECTRIC TYPE: Heater 1 and
heater 2 are energized - 5400 W
GAS TYPE: Gas valve is energized
(Temperature in the drum is
displayed in degrees C.)
ACTIVATING THE DIAGNOSTIC TEST MODE
1. UNIT must be in standby (unit plugged in, dispaly off)
2. press POWER while pressing MORE TIME and LESS TIME simultaneously.
3. press START/PAUSE button to advance through diagnostics.