![background image](http://html.mh-extra.com/html/lg/cj44/cj44_service-manual_220314010.webp)
POWER ON
VFD “NO DISC” status
It is possible at any function.
(ex. It is possible at VFD “NO USB” status, too.)
This is an example.
Front ‘Stop’ + Remote control ‘ ’
push same timing during 5 s
FLD “OP00-…..”
Move to appropriate position
And make changes with remote control
“ , , , REPEAT” key.
Press ‘Stop’ Key
VFD “WRITE OK”
Front ‘Stop’ + Remote control ‘ ’
push same timing during 5 s
VFD “E2P CLR”
Completed
1-9
SERVICE INFORMATION FOR EEPROM
/
NAME
OPT0
OPT1
OPT2
OPT3
OPT4
OPT5
OPT6
OPT7
OPT8
OPT9
OPT10
OPT11
OPT12
OPT13
OPT14
DETECT NEW EEPROM
(OPTION EDIT SCREEN)
HEX
01(LGEAP)/11(LGERA)
31
2D
26(LGEAP)/22(LGERA)
19
00
00
43
4A
34
00
00
00
00
00
Summary of Contents for CJ44
Page 17: ...2 2 ...
Page 19: ...2 6 2 5 ...
Page 21: ...2 8 A60 3 SPEAKER SECTION FRONT SPEAKER ...
Page 55: ...3 28 ...
Page 58: ...3 33 3 34 2 SMPS BLOCK DIAGRAM ...
Page 62: ...3 41 3 42 2 MAIN P C BOARD DIAGRAM TOP VIEW BOTTOM VIEW ...
Page 63: ...3 43 3 44 3 FRONT P C BOARD DIAGRAM TOP VIEW BOTTOM VIEW ...
Page 64: ...3 45 3 46 4 MIC P C BOARD DIAGRAM TOP VIEW BOTTOM VIEW ...
Page 65: ...3 47 3 48 ...