THE INDOOR UNIT INSTALLATION
7
THE INDOOR UNIT INSTALLATION
ENGLISH
CAUTION
!
• Install the unit horizontally using a level
gauge.
• During the installation, care should be
taken not to damage electric wires.
• Select and mark the position for fixing
bolts and piping hole.
• Decide the position for fixing bolts
slightly tilted to the drain direction after
considering the direction of drain hose.
• Drill the hole for anchor bolt on the wall.
NOTE
!
• Avoid the following installation location.
1. Such places as restaurants and kitchen
where considerable amount of oil
steam and flour is generated.
These may cause heat exchange effi-
ciency reduction, or water drops, drain
pump mal-function.
In these cases, take the following
actions;
• Make sure that ventilation fan is enough
to cover all noxious gases from this
place.
• Ensure enough distance from the cook-
ing room to install the air conditioner in
such a place where it may not suck oily
steam.
2. Avoid installng air conditioner
in such places where
cooking oil or iron powder is
generated.
3. Avoid places where
inflammable gas is generated.
4. Avoid place where noxious gas is
generated.
5. Avoid places near high frequency
generators.
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table
Air conditioner
Take enough
distance
Summary of Contents for AVNQ18GJLA1
Page 16: ...Memo ...
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ... ข อควรระวังเมื อวางสายไฟ ...
Page 22: ......
Page 23: ......
Page 24: ......
Page 26: ......
Page 27: ...นํ า นํ า นํ า ปลายของท อระ บายนํ าจุ มอยู ใน นํ า นํ า นํ า แท นยึด ...
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......