8
CARRYING METHOD
ENGLISH
CAUTION
Be very careful while carrying the product.
• Do not have only one person carry product if it is more than 20 kg.
• PP bands are used to pack some products. Do not use them as
a mean for transportation because they are dangerous.
• Do not touch heat exchanger fins with your bare hands.
Otherwise you may get a cut in your hands.
• Tear plastic packaging bag and scrap it so that children cannot
play with it. Otherwise plastic packaging bag may suffocate
children to death.
• Place extra cloth or boards in the locations where the casing
comes in contact with the sling to prevent damage.
!
• Fix the unit tightly with bolts as shown below so that unit will not fall
down due to earthquake or gust.
• Use the H-beam support as a base support
• Noise and vibration may occur from the floor or wall since vibration is
transferred through the installation part depending on installation
status. Thus, use anti-vibration materials (cushion pad) fully (The base
pad shall be more than 200mm).
At least 200mm
Unit : mm
200
75
75
200
100
Ⓐ
The corner part must be fixed firmly. Otherwise, the support for the
installation may be bent.
Ⓑ
Get and use M10 Anchor bolt.
Ⓒ
Put Cushion Pad between the outside unit and ground support for
the vibration protection in wide area.
Ⓓ
Space for pipes and wiring (Pipes and wirings for bottom side)
Ⓔ
H-beam support
Ⓕ
Concrete support
WARNING
• Install where it can sufficiently support the weight of the
compressor module.
If the support strength is not enough, the compressor module
may drop and hurt people.
• Install where the compressor module may not fall in strong
wind or earthquake.
If there is a fault in the supporting conditions, the outside unit
may fall and hurt people.
• Please take extra cautions on the supporting strength of the
ground and the passages of the pipe and wiring, when making
the ground support.
!
Foundation for Installation
Front panel
a
c d
b
ARUN050LMC0
a
580
b
530
c
500
d
462
e
25
[Unit : mm]
At le
ast 10
0mm
At le
ast 10
0mm
At le
ast 10
0mm
For outdoor units
should not be
supported only
by the corner
supports.
Center of the Unit
At le
ast 1
00m
m
At le
ast 1
00m
m
At le
ast 1
00m
m
Center of the Unit
The location of the Anchor bolts
INSTALLATION : COMPRESSOR
MODULE
• You can install the compressor module directly on the floor or on a
structure. If you want to install on floor, you do not use ancor bolt.
• Install at places where it can endure the weight and vibration/noise
of the compressor module.
• The compressor module supports at the bottom shall have width of
at least 100mm under the Unit’s legs before being fixed.
• The compressor module supports should have minimum height of
200mm.
• Anchor bolts must be inserted at least 75mm.
CARRYING METHOD
• Please transport the product referring to the figure.
• Use only accessories and parts which are of the designated
specification when installing.
Compressor Module.
Heat Exchanger Module.
www.lgcomfortcooling.co.uk