1. Specification
Specification
HP
Model Name
Combination Unit
Capacity
1)
(Rated)
Cooling
kW
kcal/h
Btu/h
Heating
kW
kcal/h
Btu/h
Input (Rated)
1)
Cooling
kW
Heating
kW
EER
COP
Power Factor
6)
Rated
-
Casing Color
Heat Exchanger
Compressor
Type
Piston Displacement
cm
3
/rev
Number of Revolution
rev/min
Motor Output
W
Starting Method
Oil Type
Oil Charge
Fan
Type
Motor Output x Number
W
Air Flow Rate(High)
m
3
/min
ft
3
/min
Drive
Discharge
Side / Top
Piping
Connections
Liquid
mm(inch)
Gas
mm(inch)
Dimensions(W x H x D)
mm
inch
Net Weight
kg
lbs
Sound Pressure
Level
Cooling
dB(A)
Heating
dB(A)
Sound Power Level
dB(A)
Protection
Devices
High pressure
protection
-
High pressure sensor /
High pressure switch
High pressure sensor /
High pressure switch
High pressure sensor /
High pressure switch
Comperssor/ Fan
-
Over-heat protection /
Fan driver overload protector
Over-heat protection /
Fan driver overload protector
Over-heat protection /
Fan driver overload protector
Inverter
-
Over-heat protection /
Over-current protection
Over-heat protection /
Over-current protection
Over-heat protection /
Over-current protection
Communication Cable
No.xmm
2
(VCTF-SB)
Refrigerant
Refrigerant name
Precharged Amount
kg
lbs
Control
Power Supply
V, Ø, Hz
Number of maxmum connectable indoor units
2)
Notes:
1. Eurovent Test Condition : Maximum 4 Indoor units are connected (Indoor unit type
is only Ceiling Concealed Duct)
- Refer to EUROVENT certification regulation for more detail test conditions.
- Performances of Combination units are sum of Independent unit(Outdoor Units).
2. Performances are based on the following conditions :
- Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB
Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB
- Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB
Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
3. The maximum combination ratio is 160%.
4. Wiring cable size must comply with the applicable local and national codes.
5. Due to our policy of innovation some specifications may be changed without notification.
6. Sound Level Values are measured at Anechoic chamber. Therefore, these values
can be increased owing to ambient conditions during operation.
7. Power factor could vary less than ±1% according to the operating conditions.
8. This product contains Fluorinated greenhouse gases.
4
5
6
ARUN040GSS0
ARUN050GSS0
ARUN060GSS0
12.1
14.0
15.5
10,400
12,000
13,300
41,200
47,800
52,900
12.5
16.0
18.0
10,800
13,800
15,500
42,700
54,600
61,400
3.57
3.51
4.18
2.91
3.60
4.31
3.39
3.99
3.71
4.3
4.44
4.18
0.93
0.93
0.93
Warm Gray
Warm Gray
Warm Gray
Gold fin
Gold fin
Gold fin
BLDC Inverter Twin Rotary
BLDC Inverter Twin Rotary
BLDC Inverter Twin Rotary
44.2
44.2
44.2
3,600
3,600
3,600
4,000
4,000
4,000
DC Inverter Starting
DC Inverter Starting
DC Inverter Starting
FVC68D(PVE)
FVC68D(PVE)
FVC68D(PVE)
1,300
1,300
1,300
Axial Flow Fan
Axial Flow Fan
Axial Flow Fan
124 x 1
124 x 2
124 x 2
60
110
110
2,119
3,885
3,885
DC INVERTER
DC INVERTER
DC INVERTER
Side
Side
Side
Ø 9.52(3/8)
Ø 9.52(3/8)
Ø 9.52(3/8)
Ø 15.88(5/8)
Ø 15.88(5/8)
Ø 19.05(3/4)
950 × 834 × 330
950 × 1,380 × 330
950 × 1,380 × 330
37-13/32 × 32-27/32 × 13
37-13/32 × 54-11/32 × 13
37-13/32 × 54-11/32 × 13
69
94
94
152
207
207
50
51
52
52
53
54
62
66
67
2C x 1.0 ~ 1.5
2C x 1.0 ~ 1.5
2C x 1.0 ~ 1.5
R410A
R410A
R410A
1.8
3.0
3.0
4.0
6.6
6.6
Electronic Expansion Valve
Electronic Expansion Valve
Electronic Expansion Valve
220-240 , 1 , 50
220-240 , 1 , 50
220-240 , 1 , 50
220, 1, 60
220, 1, 60
220, 1, 60
8
10
13