THE INDOOR UNIT INSTALLATION
THE INDOOR UNIT INSTALLATION
Installation of Unit
Install the unit above the ceiling correctly.
Position of suspension Bolt
- Apply a joint-canvas between the unit and
duct to absorb unnecessary vibration.
- Apply a filter Accessory at air return hole.
[Unit:mm(inch)]
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local
supply)
X 4
M10 Nut
M10 SP. washer
M10 washer
X 4
X 4
(Local
supply)
X 4
Drainage hole
A
B
C
D
(G)
E
F
Inspection
Port
Indoor Unit
Ceiling
Canvas
Duct
Air Intake
Port
Ceiling
B
oard
Ceiling
B
oard
Air Discharge
Port
Discharge
Duct
Intake
Duct
body
filter
Joint canvas
Main duct
H
I
J
24 k / 36 k
A
1,232 (48-1/2)
B
1,182 (46-17/32)
C
355 (13-31/32)
D
45.5 (1-25/32)
E
450 (17-23/32)
F
30 (1-3/16)
G
87 (3-7/16)
H
830 (32-11/16)
I
186 (7-5/16)
J
298 (11-23/32)
Dimension
Capacity
Case 1
- Install the unit leaning to a drainage hole side
as a figure for easy water drainage.
Position of console Bolt
- A place where the unit will be leveled and
that can support the weight of the unit.
- A place where the unit can withstand its
vibration.
- A place where service can be easily per-
formed.
Case 2