Maintenance and Service
Owner’s Manual
9
ENGLISH
Plasma filter
Air filter
Wired Remote Controller
(Accessory)
Air inlet
Air outlet
Panel, Case, and Remote Control
o
Turn the system off before cleaning. To clean, wipe
with a soft, dry cloth. Do not use bleach or
abrasives.
Supply power must be disconnected
before cleaning the indoor unit.
NOTICE
1. Remove air filters.
o
Take hold of the tab and pull slightly forward to
remove the filter.
When the air filter is to be removed, do not
touch the metal parts of the indoor unit.
It may cause an injury.
2. Remove plasma filter.
o
Unscrew 2 screws from plasma filter.
3. Clean dirt from the air filter using a vacuum
cleaner or washing with water.
o
If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
o
If hot water (50 °C or more) is used, it may be
deformed.
4. After washing with water, dry well in the
shade.
o
Do not expose the air filter to direct sunlight or
heat from a fire when drying it.
5. Install plasma filter and air filter.
CAUTION
Air Filter
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or more
often if neccessary.
Before performing any maintenance, turn off the main power to the system.
CAUTION
o
Never use any of the followings:
•
Water hotter than 40 °C.
Could cause deformation and/or
discoloration.
•
Volatile substances.
Could damage the
surfaces of the air
conditioner.
TT chassis : 6EA Rack
TU chassis : 4EA Rack
Maintenance and Service( Panel Type)
B enzene
SCOURING C
CLBARGERG C
S IN
NER
Summary of Contents for ARNU07GTUB4
Page 12: ...12 Indoor Unit ...