57 Installation
Installation of unit
6RWU0-06A
PTAC
• Unit Installation
• When the air conditioner has been running and is turned off or set to the fan position, wait at least 3 minutes
before resetting to the cooling & heating operations.
Note
A slight heat odor may come from the unit when first switching to HEAT after the cooling season is over. This
odor, caused by fine dust particles on the heater, will disappear quickly. This is harmless.
• PTAC exhausting discharge air in balcony that is closed off with glass or panels.
This causes hot air to be pulled back into the Outdoor air intake.
Note
This effect will reduce the cooling efficiency.
In order to work correctly, installer or customer will have to remove glass panels to better exhaust hot air.
• Failure to follow this caution may result in equipment damage or improper operation.
• Blocking indoor(curtain or bedclothes etc.) or outdoor discharge air could cause premature failure of unit.
• If there has a gap between rear side of product & outside wall, the air splitter need to be used on unit.
Indoor Outdoor
Greenhouse Effect
Enclosed outdoor area
Glass or
panels
IN
DO
OR
IN D OO R
Sleeve
Wall
Outside Wall
Air Splitter
Rear side of product