General Information
Description
Indoor unit(Internal)
474
848
305
66
39
75.1
100
81
76
109
52
474
No
Name
Remarks
1
Refrigerant Pipe
Ø15.88mm
2
Refrigerant Pipe
Ø9.52mm
3
Entering Water Pipe
Male PT 1 inch
4
Leaving Water Pipe
Male PT 1 inch
5
Control Panel
Built-in Remote Controller
6
Water Pump
Max Head 7.5 / 6.5 m
7
Safety Valve
Open at water pressure 3 bar
8
8'
T
Thermal switch
hermal switch
Cut-off power input to electric heater at 90 C (manual return at 55C)
(1Ø Electric Heater is applied)
Cut-off power input to electric heater at 90 C (manual return at 55 C)
(3Ø Electric Heater is applied)
9
Control Box
PCB and terminal blocks
10
Flow Switch
Minimum operation range at 12 LPM. (9kW)
Minimum operation range at 15 LPM. (12kW, 14kW, 16kW)
11
Plate Heat Exchanger
Heat exchange between refrigerant and water
12
Pressure Gage
Indicates circulating water pressure
13
Expansion Tank
Absorbing Volume change of heated water
14
Air Vent
Air purging when Charging water
15
Electric Heater
Please refer Page 12
16
17
Strainer
Shut-off valve
18
Carrying handle
Filtering and stacking particles inside circulating water
To drain or to block water when pipe connecting
To carry the product
(unit:mm)
20
Air-to-Water Heat Pump
Summary of Contents for AHNW096A0
Page 92: ...92 Air to Water Heat Pump ...
Page 93: ......