- 77 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Uses of sensors
: Control of compressor and cycle
2. Kinds of Sensors (See corresponding pages)
Outlet : 200KΩ ± 10%
Piping : 5KΩ ± 10%
Air : 10KΩ ± 10%
(Based on 25℃ of surrounding temperature)
3. Sensor insulation resistance
: The resistance between the sash and sensor terminal should be not less than 1MΩ.
Items
Contents
Purpose
Prevention of reception of wrong temperature value from the tempera
-
ture sensor
Condition for GenerationDamage of temperature sensor (Short / Open)
Condition for Generation
Classification
Causes in Detail
PCB Assembly
Connector open, damaged insulation of sash, damage of the wire coat
-
ing of temperature sensors
Code No.
Details of Errors
41
Inverter Discharge temperature sensor Open/Short
43
High pressure Sensor Error
44
Outdoor air temperature sensor Open/Short
45
Outdoor piping temperature sensor Open/Short
46
Outdoor suction temperature sensor Open/Short
48
Cond. Out-Pipe temperature Sensor Error
Cause of Temperature Sensor Error
Checking Temperature Sensor Open/Short
6.6 Troubleshooting Outdoor Error
Part 4 Trouble Shooting