2. Ceiling dimension and hanging
bolt location
■
Installation of Unit
Install the unit above the ceiling correctly.
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
• Install the unit leaning to a drainage hole side as a
figure for easy water drainage.
• A place where the unit will be leveled and that can
support the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.
CASE 1
POSITION OF SUSPENSION BOLT
CASE 2
POSITION OF CONSOLE BOLT
(Unit:mm)
Q
G
R
169
T
E
P
Flat washer
(Zinc plated)
3mm steel chain
1/4" coach
screw
(Self-tapping
wood screw
with hexagonal
head)
Flat washer
(Zinc plated)
Flat washer
(Zinc plated)
Flat washer
(Zinc plated)
2˚
2˚
M6
(Zinc plated)
screw & Nut
M6
(Zinc plated)
screw & Nut
Galvanized steel
(Pre-punched) strap
1/4" coach
screw
(Self-tapping
wood screw
with hexagonal
head)
Flat washer
(Zinc plated)
Self-tapping
screw or M6
(Zinc plated)
screw & Nut
Self-tapping
screw or M6
(Zinc plated)
screw & Nut
TYPE-A (Using steel chain)
TYPE-B (Using Galvanized steel strap)
NOTE:
• Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount
of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dis-
persing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a
cooking table has sufficient capacity so that it draws oily steam
which should not flow into the suction of the air conditioner.
• Make enough distance from a cooking room to install the air
conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cut-
ting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is
stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
LBNS3061BL
482
282
718
798
798
-
120
LBNS3062BL
712
284
868
934
937
548
120
LBNS3063BL
712
284
868
934
937
548
120
LBNS3064BL
712
284
868
934
937
548
120
LBNK3661BL
712
284
868
934
937
548
120
ABNH366KSA0
712
284
868
934
937
548
120
LBNK4881BL
712
284
868
934
937
548
120
LBNK4882BL
712
327
935
1014
1014
567
130
LBNK4883BL
712
327
935
1014
1014
567
130
LBNH608RSS1
1004
303
1093
1270
1281
1475
105
LBNH608RSS3
1004
303
1093
1270
1281
1475
105
LBNM7280BL
833
327
1221
1313
1313
567
130
LBNM7281BL
833
327
1221
1313
1313
567
130
LBNM9080BL
835
377
1403
1504
1504
-
190
LBNM9081BL
835
377
1403
1504
1504
-
190
LBNM1080BL
835
377
1403
1504
1504
-
190
LBNM1081BL
835
377
1403
1504
1504
-
190
E
F
G
P
Q
R
T
Dimension
Model No.