Function
ENGLISH
Saving Power Consumption Current level.
Night Quiet Mode operation lowers the noise level of the outdoor unit by changing the comp
frequency and fan speed. This function is operated all night long.
Setting Procedure
1. Set the DIP Switch as follow after shutting the power source down.
2. Reset the power.
Night Quiet Mode with Mode Lock.
Saving Power Consumption with Mode Lock.
Phase
1Ø
Model
18/24 k
30/36 k
48/54/60 k
Step 1(A)
15
13
22
Step 2(A)
14
11
21
Mode Lock (Cooling) +
Night Quiet Mode (step 1)
Mode Lock (Cooling) +
Night Quiet Mode (step 2)
Step 1
Step 2
h
Noise level :
Step 1 > Step 2
Night Quiet Mode
CAUTION
• If comp frequency and fan speed are down, the cooling capacity may decrease
accordingly.
• This function is only available for Cooling Mode.
• If you want to stop the Night Quiet Mode, Change the DIP Switch.
• If operating indoor unit is set by the fan speed “Power”, Night Quiet Mode will
be stopped until fan speed “Power” is changed.
!