38
FUNCTION
ENGLISH
PCB Display(18 / 26 k Model Only)
It is useful to check the cycle data without LGMV.
Whenever you push the Tact Switch, the cycle information will be shown as below.
h
After 1 page is displayed, subsequently 2 page is displayed.
TACT-SW1
Item
Display
Case 1
Case 2
Example
1page
2page
-
1 time
Low Pressure
890 kPa
‘LP’
’ 89’
-
2 times
Hi Pressure
2 900 kPa
‘HP’
‘290’
1 time
3 times
Discharge Temp.
85 °C
‘DS’
’ 85’
2 times 4 times
Cond Out Temp.
-10 °C
‘CS’
‘-10’
3 times 5 times
Suction Temp.
-10 °C
‘SS’
‘-10’
4 times 6 times
ODU Air Temp.
-10 °C
‘AS’
‘-10’
5 times 7 times
Current
15 A
‘A’
‘ 15’
6 times 8 times
Voltage
230 V
‘V’
‘230’
7 times 9 times
Comp Hz
100 Hz
‘F’
‘100’
8 times 10 times
DC Link Voltage
230 V
‘dc’
‘230’
TACT-SW1
When you push the Tact Switch, use the material non-conducting electricity.
WARNING
!
Operating Method
Case 1 : 18k 2Room
Case 2 : Others
Summary of Contents for A4UQ28GFA0