ENGLISH
59
ENGLISH
TO CONTROL MULTIPLE PRODUCTS
Use this method to connect several products to a single PC. You can control several products at a time by connecting
them to a single PC.
In the Installation menu, the Set ID must be between 1 and 1000 without being duplicated.
Connecting the cable
Connect the RS-232C cable as shown in the picture.
The RS-232C protocol is used for communication between the PC and product. You can turn the product on or off,
select an input source or adjust the OSD menu from your PC.
Monitor 1
Monitor 2
Monitor 3
Monitor 4
PC
RS-232C Cable
RS-232C Configurations
8-Wire Configurations (Standard RS-232C cable)
DCD
RXD
TXD
GND
DTR
DSR
RTS
CTS
DCD
TXD
RXD
GND
DSR
DTR
CTS
RTS
PC
Set
1
2
3
5
4
6
7
8
1
3
2
5
6
4
8
7
D-Sub 9 D-Sub 9
(Female) (Female)
Communication Parameter
Baud Rate: 9600 BPS
Data Length: 8 bit
Parity Bit: None
Stop Bit: 1 bit
Flow Control: None
Communication Code: ASCII code
Use a crossed (reverse) cable
NOTE
•
When using three-wire connections (non-standard),
an IR daisy chain cannot be used.
•
When monitors connected via Daisy Chain (that
controls multiple monitors) are turned off and on
successively, some monitors may not turn on. In this
case, you can turn those monitors on by pressing
the
MONITOR ON
button, not the
POWER
button.
ID
BACK
TILE
ON
OFF
EXIT
MONITOR ON
(POWER)