- 13 -
LGE Internal Use Only
Copyright LG Electronics. Inc. All right reserved.
Only for training and service purposes
5.3 Option selection per country
5.3.1 Overview
• Option selection is only done for models in Non-USA North
America due to rating
• Applied model: LA01U Chassis applied None USA
model(CANADA, MEXICO)
5.3.2 Method
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is
done using +, - KEY
5.4 Tool Option selection
• Method: Press Adj. key on the Adj. R/C, then select Tool
option.
6. GND and Hi-pot Test
6.1. Method
6.1.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE
insertion condition
6.1.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV
CORD is tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test).
(Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next
process automatically.
6.2. Checkpoint
• TEST voltage
- GND: 1.5KV/min at 100mA
- SIGNAL: 3KV/min at 100mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
- Internal Pressure TEST = POWER CORD GND & LIVE &
NEUTRAL
• LEAKAGE CURRENT: At 0.5mArms
7. EYE-Q Check
Step 1) Turn on the TV.
Step 2) Press EYE button in adjust remote control.
Step 3) Stay 6 seconds with Eye Q sensor hidden located on
the front of the set.
Step 4) Check the “Sensor Data” on the screen and check
whether the value is lower thanafter 6 seconds, the
value does not go below 10, Eye Q sensor is not
working properly. Then, change the sensor.
Step 5) Remove hand from the Eye Q II sensor and stay for 6
seconds.
Step 6) Check whether the “Back Light (xxx)” value has risen
on the screen. If after 6 seconds and the value still
does not go high, the eye Q II sensor is not working
properly. Replace the sensor.
42LV355C -UA
55LV355C - UA
Tool 1
26464
46944
Tool 2
10774
10774
Tool 3
53291
53290
Tool 4
2332
2332
Tool 5
16672
24864
<Step1>
<Step2>
<Step3>
<Step4>
<Step5>