91
July 2010 50PJ350 Plasma
Control P111 to Y
Control P111 to Y
-
-
SUS P101 Plug Information
SUS P101 Plug Information
Note: There are no voltages in Stand-By mode
2.84V
0.06V
I_YSUS_UP_IN
29
2.83V
0.62V
I_YER_UP
27
2.82V
0.95V
I_YSUS_DN_IN
25
2.81V
0V
I_YER_DN
23
2.81V
1.34V
I_Slope_Rate_Sel
21
2.81V
0.03V
I_Det_Level_Sel
19
2.81V
2.09V
I_SET_ON
17
2.81V
2.08V
I_Delta_VY_Det
15
Gnd
Gnd
Gnd
13
1.64V
0V
OE
11
2.98V
0V
CTRL_OE
9
1.52V
4.9V
+5V
7
1.52V
4.9V
+5V
5
Open
16V
+15V
3
Open
16V
+15V
1
Diode Check
Run
Label
Pin
P111 "Control" Odd Pins to P101 "Y-SUS"
Gnd
Gnd
Gnd
30
2.82V
1.08V
I_Pass_Top
28
2.82V
1.01V
I_Ramp_Slope_Opt1
26
2.82V
0.24V
I_SET_UP
24
2.82V
0.59V
I_CLK
22
2.84V
1.97V
I_STB
20
2.84V
1.43V
I_OC1
18
2.84V
0V
I_DATA
16
2.84V
1.78V
I_OC2
14
Gnd
Gnd
Gnd
12
Gnd
Gnd
Gnd
10
Gnd
Gnd
Gnd
8
1.4V
4.9V
+5V
6
1.4V
4.9V
+5V
4
Open
16V
+15V
2
Diode Check
Run
Label
Pin
P111 "Control" Even Pins to P101 "Y-SUS"
Diode Mode Readings taken with all connectors Disconnected. Black lead on Gnd. DVM in Diode Mode.