42
July 2010 50PJ350 Plasma
Diode Mode Readings taken with all connectors Disconnected. DVM in Diode Mode.
SMPS Connector P813 Identification, Voltages and Diode Check
SMPS Connector P813 Identification, Voltages and Diode Check
Open
Gnd
Gnd
e
Auto Gnd
18
Open
3.29V
0V
b
M_ON
17
3.06V
4.44V
0V
a d
AC Det
16
Open
2.43V
0V
RL On
15
2.55V
5.14V
3.46V
Stby 5V
13-14
Gnd
Gnd
Gnd
Gnd
9-12
3.09V
4.1V
2.85V
a c
Error Det
8
1.16V
5.17V
0.46V
a
5V
5-7
Gnd
Gnd
Gnd
Gnd
3-4
3.17V
17V
0V
a
16V
1-2
Diode Mode
Run
STBY
Label
Pin
P813 Connector “SMPS" to “Main" P301
P813
1
Note: This connector has two
rows of pins.
Odd on bottom row.
a
Note:
The 17V, 5V, AC_Det and Error Det turn on when the RL_On command arrives.
b
Note:
The M5V, Va and Vs turn on when the M_On (Monitor On) command arrives.
c
Note:
The Error Det line is not used in this model.
d
Note: If the
AC Det line is Missing, the TV will shut off after 10 seconds of operation.
e
Note: Pin 18 is grounded on the Main board. If this line is floated, the SMPS turns on
Automatically when AC is applied.