79
July 2010 50PJ350 Plasma
The Z-SUS (in combination with the Y-SUS) generates a
SUSTAIN Signal and an ERASE PULSE for generating
SUSTAIN and DISCHARGE in the Panel.
This waveform is supplied to the panel through two FPC
(Flexible Printed Circuit) connections P101 and P102 and
to the Z-SUB P3 to P7 and then to one FPC (Flexible
Printed Circuit) connections P202.
Oscilloscope Connection Point.
J36 to check Z Output waveform.
Right Hand Side Center.
Z
Z
-
-
SUS Waveform
SUS Waveform
This Waveform is just for reference to observe the effects of Zbz adjustment
Vzb voltage 95V ± 1V
Z Drive
Waveform
(Vzb) Z Bias VR201 manipulates the
offset of this waveform segment.
TIP: The Z-Bias (VZB) Adjustment is a
DC level adjustment.
This is only to show the effects
of Z-Bias on the waveform.
Reset
Y Drive
Waveform