* Connecting picture of the measuring instrument (On Auto-
matic control)
- Inside PATTERN is used when W/B is controlled. Con-
nect to auto controller or push Adjustment R/C POWER-
ON -> Enter the mode of White-Balance, the pattern will
come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 100Lux).
2) Adhere closely the Color Analyzer ( CA210 ) to the
module less than 10cm distance, keep it with the surface
of the Module and Color Analyzer’s Prove vertically.
(80~100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
■ Auto adjustment Map(RS-232C)
RS-232C COMMAND
[ CMD ID DATA ]
Wb 00 00 White Balance Start
Wb 00 ff White Balance End
*Caution
- Color Temperature : COOL, Medium, Warm.
- One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
( when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
■ After enter Service Mode by pushing “ADJ” key,
■ Enter White Balance by pushing “►” key at “6. White
Balance”.
* After You finish all adjustments, Press “In-start” button and
compare Tool option and Area option value with its BOM, if it
is correctly same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug
AC cable.
For correct it to the model’s module from factory JIG model.
* Push The “IN STOP KEY” after completing the function
inspection. And Mechanical Power Switch must be set “ON”.
4.2. MAC Address Download
■ Com 1,2,3,4 and 115200(Baudrate)
■ Port connection button click(1)
■ Load button click(2) for MAC Address write.
■ Start MAC Address write button(3)
■ Check the OK Or NG
4.3. LAN (Automatic IP)
4.3.1. Equipment & Condition
■ Each other connection to LAN Port of IP Hub and Jig
4.3.2. LAN inspection solution
■LAN Port connection with PCB
■ Network setting at MENU Mode of Menu
- “menu” key input -> Network -> Network Setting ->
Press “Enter” -> IP Auto Setting -> OK
■ setting automatic IP
■ Setting state confirmation
- If automatic setting is finished, you confirm IP and
MAC Address.
RS-232C
COMMAND
[CMD ID DATA]
M
I
N
CENTER
(DEFAULT)
M
A
X
Cool Mid Warm
Cool Mid Warm
R Gain
jg
Ja
jd
00
172 192
192
192
G Gain
jh
Jb
je
00
172 192
192
192
B Gain
ji
Jc
jf
00
192 192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128