APPENDIX
109
2
20
0.. B
Blluuee aad
djjuussttm
meenntt((C
Co
om
mm
maannd
d::$
$))
To adjust blue in color temperature.
Transmission
[k][$][ ][Set ID][][Data][Cr]
Data Min:0
~
Max:C8
*Refer to "Real data mapping 2". See page 108.
Acknowledgement
[$][ ][Set ID][][OK/NG][Data][x]]
*Real data mapping 2
0 : -20
5 : -19
A : -18
5F: -1
64: 0
69: +1
C3 : +19
C8 : +20
2
21
1.. IISSM
M M
Meetthho
od
d//O
Orrb
biitteerr ((C
Co
om
mm
maannd
d2
2::p
p))
(Only Plasma TV model)
To avoid having a fixed image remain on screen.
Transmission
[ j ][p][ ][Set ID][ ][Data][Cr]
Data 1: Inversion 2: Orbiter
4: White Wash 8: Normal
Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]
2
22
2.. LLo
ow
w PPo
ow
weerr ((C
Co
om
mm
maannd
d2
2::q
q))
(Only Plasma TV model)
To control the low power function on/off.
Transmission
[ j ][q][ ][Set ID][ ][Data][Cr]
Data 0: low power off
1: low power on
Acknowledgement
[q][ ][Set ID][ ][OK/NG][Data][x]
2
23
3.. T
Tuunnee C
Co
om
mm
maannd
d ((C
Co
om
mm
maannd
d:: m
m aa))
To tune channel to following physical/major/minor num
ber.
Transmission
[m][a][ ][Set ID][ ][Data0][ ][Data1]
[ ][Data2][ ][Data3][ ][Data4][ ][Data5][Cr]
Data 0: Physical Channel Number(Transmit by
Hexadecimal code)
NTSC air:02
~
45
NTSC cable: 01, 0E
~
7D
ATSC air:01
~
45
ATSC cable:01
~
87
Data1,Data2: Major Channel Number (two part) /
Channel Number (One part)
Data1: High byte
Data2: Low byte
Two part channel number:
Major number-Minor number
One part channel number:
If the channel band is ATSC digital cable, it can
be used. In case of using one part channel num-
ber, minor channel does not need.
Data3, Data 4: Minor Channel Number