D. Function error
Remote control & Local switch checking
Y
N
1. Remote control(R/C) operating error
Check R/C itself
Operation
Y
Replace R/C
If R/C operate,
Explain the customer
cause is interference
from light in room.
Check R/C Operating
When turn off light
in room
Check & Replace
Baterry of R/C
Connector solder
☞
A17
N
N
Check +5V on main board
replace main board or change
IR SERSOR
Output signal
N
Y
Repair/Replace
IR B/D
N
Replace
Main B/D
Y
Standard Repair Process
Established
date
Revised date
11/14
L
E
D TV
Error
symptom
201
4
. 0
7.07
End
Normal
Operating
Normal
Voltage
Normal
Signal
Normal
Operating
Normal
Operating
End
Y
Copyright © 2014 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Check +5V for
IR Sensor