Floor Standing type Air Conditioner
Installation of Unit
Connecting the Cable to Indoor Unit
• The inside and outside connecting cable can be connected after opening the inlet grille.
5
4
3
2(N)
1(L)
7
6
5
4(L2)
3(L1)
5
4
3
2(N)
1(L)
(America, Canada only)
Outdoor unit
Outdoor unit
Outdoor unit
Insert the plastic tube
(America, Canada only)
1. Open the inlet grille manually.(Fig.1)
2. Open the terminal block cover with driver(
).
3. Connect the cables(LG doesn't sypply) to the Terminal Block in the front Bracket. (Fig.2)
4. Secure the terminal block cover to the original position with the screw.
5. Insert the plastic tube(Bushing)in small hole in order to prevent the connecting wires
from being cut by sharp edge of the hole. (Fig. 3) , America, Canada only.
6. Close the inlet grille.
(Fig.1)
(Fig.3)
Detail Wiring of Fig.2
1. Cooling Model
2. Heating Model
(Fig.2)