Connecting Electric Dryers (cont.)
USA only
w
WArNiNg
•
Connect the power cord to the terminal block.
Connect each power cord wire to the terminal
block screw that has the same colored wire. For
example, connect the black power cord wire to the
terminal block screw with the black wire. Failure
to follow these instructions may result in a short,
overload, fire or death.
•
grounding through the neutral conductor is
prohibited for: (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and
(4) areas where local codes prohibit grounding
through the neutral conductor.
three-wire connection for electric dryers:
power cord
• A 3-wire connection is NOT permitted on new
construction after January 1, 1996.
• A UL-listed strain relief is required.
1. Remove the terminal block access cover on the
upper back of the dryer. Install a UL-listed strain relief
into the power cord through-hole; then thread a UL-
listed,
30 A, 240 V, 3-wire, #10 AWg-minimum
copper
conductor power cord through the strain
relief.
• Use a
30 A, 240 V, UL-listed power cord with #10
AWg-minimum copper
conductor and closed loop or
forked terminals with upturned ends.
2. Attach the two hot leads of the power cord to the
outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external
ground (if required by local codes) to the green
ground screw.
TIgHTEN ALL SCREWS SECURELY
.
Reinstall the terminal block access cover.
UL-Listed
Strain Relief
UL-Listed
3-Wire Power
Cord
Terminal
Block
Ground
Screw
Neutral
(White)
Hot
(Black)
Hot
(Red)
External Ground
Wire (If required
by local codes)
White Wire
from Dryer
harness
iNSTALLATiON
MFL67731093_en_170718.indd 28
2017.7.18 1:52:8 PM
Summary of Contents for DleX9500 Series
Page 52: ...MFL67731093_en_170718 indd 52 2017 7 18 1 52 53 PM ...
Page 104: ...52 MFL67731093_sp_170718 indd 52 2017 7 18 2 12 42 PM ...
Page 105: ...53 ESPAÑOL MFL67731093_sp_170718 indd 53 2017 7 18 2 12 42 PM ...
Page 106: ...54 MFL67731093_sp_170718 indd 54 2017 7 18 2 12 42 PM ...
Page 107: ...MFL67731093_sp_170718 indd 55 2017 7 18 2 12 42 PM ...